FDS Simulation for Building Fire Safety: From Fire Growth to Smoke Movement

FDS Simulation for Building Fire Safety | HyperCurve
FDS · Fire Safety Engineering · 2026

FDS simulation for building fire safety.

From fire growth to smoke movement: understand how Fire Dynamics Simulator models a developing fire and the smoke spreading through a building.

A fire alarm tells people a fire exists. It does not show how much time remains before a corridor fills with smoke or whether a stairwell stays clear. FDS helps engineers model that changing environment and assess conditions along escape routes.

Key takeaways

Fire growth and smoke movement are connected.

  • FDS models a coupled process: heat release drives a buoyant plume, which drives smoke movement through the building.
  • The heat release rate curve strongly influences downstream results.
  • Smoke can spread through corridors, stairwells and shafts before flames reach those areas.
  • Results are assessed against tenability criteria for temperature, visibility and toxic gas concentration.
01 · Fundamentals

What FDS actually models

Fire Dynamics Simulator is a computational fluid dynamics tool designed for fire-driven flows. It solves a low-speed, thermally driven form of the Navier–Stokes equations, coupled with combustion and radiation models.

Ignition → Heat release → Buoyant plume → Hot gas layer → Smoke spread

That chain summarises the simulation: heat released by a fire drives a plume, the plume forms a hot gas layer beneath the ceiling, and that layer spreads through connected openings and corridors.

Fire source

Combustion and heat release

The fire scenario defines how energy is released over time and how much soot and combustion gas may be produced.

Flow field

Plume and smoke transport

Buoyancy, pressure differences and ventilation influence the movement of hot gases through the modelled space.

Assessment

Conditions over time

Simulation outputs can be evaluated at key locations along corridors, stairwells and escape routes.

02 · Fire development

Fire growth: from ignition to peak heat release

Every FDS fire scenario starts with a heat release rate (HRR) curve: how much energy the fire releases per second as a function of time. Many design fires use a t-squared growth profile, where heat release increases with the square of time until it reaches a specified peak.

Growth rate Time to reach 1,055 kW Typical fuel example
Slow Approximately 600 s Thick solid materials, tightly packed
Medium Approximately 300 s Upholstered furniture, mattresses
Fast Approximately 150 s Thin plastics, loosely packed combustibles
Ultra-fast Approximately 75 s Flammable liquids, some foam products
The growth curve drives downstream results Plume strength, hot gas layer temperature and smoke production are influenced by the heat release rate. If the selected curve does not represent the expected fuel load, predicted smoke movement and evacuation conditions may not reflect the intended scenario.
03 · Smoke transport

Smoke movement through the building

Smoke can reach occupants long before flames do. Once a hot gas layer forms beneath the ceiling, it can spread along corridors, into connected spaces and vertically through stairwells and shafts.

Buoyancy-driven spread

Hot smoke rises and accumulates beneath ceilings, spreading outward as the layer develops.

Stack effect in stairwells and shafts

Temperature differences between floors can drive vertical smoke movement through connected spaces.

Mechanical ventilation interaction

HVAC systems and smoke control fans can clear a space or potentially move smoke towards protected escape routes, depending on the scenario and system operation.

Impact on escape routes

Smoke movement analysis helps assess conditions along corridors, stairwells and other egress paths over time.

Why this matters for egress design Available safe egress time (ASET) is assessed by determining when conditions along an escape route reach the selected tenability limits. Fire growth and smoke movement need to be considered together.
04 · Occupant safety

Tenability: when conditions become unsafe

FDS outputs become useful for fire safety assessment when they are compared with appropriate tenability criteria: conditions beyond which occupants may no longer be able to evacuate safely.

Tenability factor Assessment focus
Smoke layer height Whether the smoke layer remains above the required clear height along egress routes
Visibility Whether visibility distance is maintained in corridors and stairways
Temperature Whether gas temperature remains below the applicable assessment threshold
Toxic gas concentration Whether carbon monoxide and other combustion gas exposures remain within applicable limits
Use project-appropriate criteria Tenability thresholds depend on the applicable guidance, occupancy, exposure duration and assessment method. Select and document the criteria relevant to the project rather than treating the table as universal limits.
05 · Model setup

Key inputs that shape the result

Geometry

Building layout and mesh

Define compartments, openings, corridors and stairwells. Refine mesh resolution near the fire source and openings where gradients may be steep.

Combustion

Fuel and soot yield

The selected fuel and soot yield influence smoke and combustion gas production, not just fire temperature.

Ventilation

Doors, windows and systems

Represent open or closed doors, windows, HVAC conditions, smoke control and pressurisation systems relevant to the scenario.

Fire location also matters The same building can produce different evacuation conditions depending on where the fire starts relative to corridors, stairwells and protected escape routes.
06 · Workflow

The FDS simulation process

A structured workflow connects the design scenario to results that can be reviewed against fire safety objectives.

1
Build the building geometry and mesh.

Model compartments, openings, corridors and stairwells, with suitable mesh resolution near the fire and openings.

2
Define the fire source.

Specify the heat release rate curve, fuel type and soot yield for the selected design fire.

3
Set ventilation and boundary conditions.

Define doors, windows, HVAC supply and extract points, and active smoke control or pressurisation systems.

4
Simulate fire growth.

Review heat release, plume development and hot gas layer formation as the fire develops.

5
Track smoke and toxic gas movement.

Record visibility, temperature and gas concentration at important locations and along egress routes.

6
Evaluate tenability.

Compare predicted conditions with the project’s selected criteria and assess whether sufficient evacuation time is available.

07 · Quality checks

Common mistakes

01 — Selecting an unsuitable HRR curve

A generic curve that does not reflect the intended fuel load can distort predicted fire development and smoke movement.

02 — Oversimplifying ventilation

Ignoring realistic door positions, openings or smoke control operation can change the predicted flow paths.

03 — Assessing fire extent instead of tenability

Evaluate temperature, visibility and gas conditions along actual egress routes, not only the location of flames.

04 — Using a mesh that is too coarse

Insufficient resolution near the fire or openings may under-resolve plume and smoke-layer behaviour. Mesh sensitivity should be considered.

08 · FAQ

Frequently asked questions

What does FDS actually solve during a fire simulation?

FDS numerically solves a form of the Navier–Stokes equations for low-speed, thermally driven flow, coupled with a combustion model for heat release and a radiation solver. Together, these models predict variables such as temperature, velocity, smoke concentration and visibility throughout the modelled space over time.

Why does the heat release rate curve matter so much?

The heat release rate curve influences plume strength, hot gas layer temperature and smoke production. A growth curve that does not represent the intended fire scenario can produce smoke movement predictions that do not reflect the scenario being assessed.

How is smoke movement different from fire growth in the simulation?

Fire growth models the combustion process and the increase in heat release at the source. Smoke movement models how hot gases spread through corridors, stairwells and shafts due to buoyancy, pressure differences and mechanical ventilation.

What tenability criteria are used to judge the results?

Common criteria include smoke layer height, visibility along escape routes, temperature and concentrations of carbon monoxide or other combustion gases. The applicable thresholds should be selected for the project and assessment method.

Fire safety engineering

Assess fire growth and smoke movement together.

HyperCurve provides FDS and CFD simulation services to support building fire safety assessments.

Explore FDS Services
© 2026 HyperCurve Engineering Team · FDS, CFD and fire safety engineering

Comments

Popular posts from this blog

Thermal Fatigue Analysis Using FEA: Predicting Failure Under Repeated Temperature Cycles

Static vs Modal vs Fatigue Analysis: Choosing the Right FEA Approach

CFD Digital Twin: Connecting Simulation to Real-Time Performance