FDS Simulation for Building Fire Safety: From Fire Growth to Smoke Movement
FDS simulation for building fire safety.
From fire growth to smoke movement: understand how Fire Dynamics Simulator models a developing fire and the smoke spreading through a building.
A fire alarm tells people a fire exists. It does not show how much time remains before a corridor fills with smoke or whether a stairwell stays clear. FDS helps engineers model that changing environment and assess conditions along escape routes.
Fire growth and smoke movement are connected.
- FDS models a coupled process: heat release drives a buoyant plume, which drives smoke movement through the building.
- The heat release rate curve strongly influences downstream results.
- Smoke can spread through corridors, stairwells and shafts before flames reach those areas.
- Results are assessed against tenability criteria for temperature, visibility and toxic gas concentration.
What FDS actually models
Fire Dynamics Simulator is a computational fluid dynamics tool designed for fire-driven flows. It solves a low-speed, thermally driven form of the Navier–Stokes equations, coupled with combustion and radiation models.
That chain summarises the simulation: heat released by a fire drives a plume, the plume forms a hot gas layer beneath the ceiling, and that layer spreads through connected openings and corridors.
Combustion and heat release
The fire scenario defines how energy is released over time and how much soot and combustion gas may be produced.
Plume and smoke transport
Buoyancy, pressure differences and ventilation influence the movement of hot gases through the modelled space.
Conditions over time
Simulation outputs can be evaluated at key locations along corridors, stairwells and escape routes.
Fire growth: from ignition to peak heat release
Every FDS fire scenario starts with a heat release rate (HRR) curve: how much energy the fire releases per second as a function of time. Many design fires use a t-squared growth profile, where heat release increases with the square of time until it reaches a specified peak.
| Growth rate | Time to reach 1,055 kW | Typical fuel example |
|---|---|---|
| Slow | Approximately 600 s | Thick solid materials, tightly packed |
| Medium | Approximately 300 s | Upholstered furniture, mattresses |
| Fast | Approximately 150 s | Thin plastics, loosely packed combustibles |
| Ultra-fast | Approximately 75 s | Flammable liquids, some foam products |
Smoke movement through the building
Smoke can reach occupants long before flames do. Once a hot gas layer forms beneath the ceiling, it can spread along corridors, into connected spaces and vertically through stairwells and shafts.
Buoyancy-driven spread
Hot smoke rises and accumulates beneath ceilings, spreading outward as the layer develops.
Stack effect in stairwells and shafts
Temperature differences between floors can drive vertical smoke movement through connected spaces.
Mechanical ventilation interaction
HVAC systems and smoke control fans can clear a space or potentially move smoke towards protected escape routes, depending on the scenario and system operation.
Impact on escape routes
Smoke movement analysis helps assess conditions along corridors, stairwells and other egress paths over time.
Tenability: when conditions become unsafe
FDS outputs become useful for fire safety assessment when they are compared with appropriate tenability criteria: conditions beyond which occupants may no longer be able to evacuate safely.
| Tenability factor | Assessment focus |
|---|---|
| Smoke layer height | Whether the smoke layer remains above the required clear height along egress routes |
| Visibility | Whether visibility distance is maintained in corridors and stairways |
| Temperature | Whether gas temperature remains below the applicable assessment threshold |
| Toxic gas concentration | Whether carbon monoxide and other combustion gas exposures remain within applicable limits |
Key inputs that shape the result
Building layout and mesh
Define compartments, openings, corridors and stairwells. Refine mesh resolution near the fire source and openings where gradients may be steep.
Fuel and soot yield
The selected fuel and soot yield influence smoke and combustion gas production, not just fire temperature.
Doors, windows and systems
Represent open or closed doors, windows, HVAC conditions, smoke control and pressurisation systems relevant to the scenario.
The FDS simulation process
A structured workflow connects the design scenario to results that can be reviewed against fire safety objectives.
Model compartments, openings, corridors and stairwells, with suitable mesh resolution near the fire and openings.
Specify the heat release rate curve, fuel type and soot yield for the selected design fire.
Define doors, windows, HVAC supply and extract points, and active smoke control or pressurisation systems.
Review heat release, plume development and hot gas layer formation as the fire develops.
Record visibility, temperature and gas concentration at important locations and along egress routes.
Compare predicted conditions with the project’s selected criteria and assess whether sufficient evacuation time is available.
Common mistakes
A generic curve that does not reflect the intended fuel load can distort predicted fire development and smoke movement.
Ignoring realistic door positions, openings or smoke control operation can change the predicted flow paths.
Evaluate temperature, visibility and gas conditions along actual egress routes, not only the location of flames.
Insufficient resolution near the fire or openings may under-resolve plume and smoke-layer behaviour. Mesh sensitivity should be considered.
Frequently asked questions
What does FDS actually solve during a fire simulation?
FDS numerically solves a form of the Navier–Stokes equations for low-speed, thermally driven flow, coupled with a combustion model for heat release and a radiation solver. Together, these models predict variables such as temperature, velocity, smoke concentration and visibility throughout the modelled space over time.
Why does the heat release rate curve matter so much?
The heat release rate curve influences plume strength, hot gas layer temperature and smoke production. A growth curve that does not represent the intended fire scenario can produce smoke movement predictions that do not reflect the scenario being assessed.
How is smoke movement different from fire growth in the simulation?
Fire growth models the combustion process and the increase in heat release at the source. Smoke movement models how hot gases spread through corridors, stairwells and shafts due to buoyancy, pressure differences and mechanical ventilation.
What tenability criteria are used to judge the results?
Common criteria include smoke layer height, visibility along escape routes, temperature and concentrations of carbon monoxide or other combustion gases. The applicable thresholds should be selected for the project and assessment method.
Assess fire growth and smoke movement together.
HyperCurve provides FDS and CFD simulation services to support building fire safety assessments.